FAQs
Frequently asked questions
PyronixCloud Connect (PCC) is a compact Wi-Fi interface that adds HomeControl2.0 app control and notifications to compatible existing wired alarm systems.
No. PCC adds connected functions to a suitable existing panel, allowing you to retain the alarm system while gaining remote control and notifications.
No. PCC works with compatible Pyronix and third-party panels. Compatibility depends on the panel’s available zone types, outputs and power supply.
For app arming and disarming, it needs a spare zone that can be programmed as a keyswitch. Suitable panel outputs are needed for alarm and armed-status information, along with an auxiliary power supply capable of powering PCC.
Yes. The wiring guide includes examples for EURO Mini, Sterling 10, Veritas 8 and R8, Veritas Compact, ION 10 and C&K 800L. Available functions depend on each panel and the connections used.
No. The installer must check the existing panel’s capabilities before installation. A panel without the required keyswitch function or suitable outputs may not provide all the intended features.
No. PCC adds app connectivity to the existing alarm. The original keypad remains available for local system operation.
Customers use HomeControl2.0, with their own PyronixCloud end-user account, to access the PCC installation.
Yes. When PCC’s relay is connected to a correctly programmed keyswitch zone, HomeControl2.0 can control arming and disarming. The panel’s keyswitch capabilities determine how this operates.
Yes, where a suitable panel output is connected and configured to report armed status. The recommended arrangement uses PCC input 2 for a ‘final set any’ signal.
Yes. PCC can send push notifications through HomeControl2.0 when its configured inputs are triggered. The event information depends on the panel outputs connected to PCC and the notification types assigned during setup.
PCC receives signals through two trigger inputs rather than a detailed feed of every detector’s activity. A general bell trigger reports an alarm event; it does not identify the individual zone that caused it.
An input can be assigned an appropriate notification type when connected to a corresponding panel output. If the input uses a general bell output, it cannot distinguish between the different events that activate that output.
Yes. Guard Response can be added to suitable PCC installations as an optional subscription service. The installer should ensure the installation is configured for the service.
PCC connects to PyronixCloud through the property’s 2.4GHz Wi-Fi network and internet connection.
No. PCC requires 2.4GHz Wi-Fi. A dual-band router can be used where a suitable 2.4GHz network is available.
No. PCC uses Wi-Fi for its internet connection. It has no Ethernet or cellular connection.
No. PCC connects through Wi-Fi, so it does not require a SIM card.
No. Bluetooth Low Energy is used during setup through HomeControl2.0. Everyday remote app communication uses PCC’s Wi-Fi connection to PyronixCloud.
Remote app control and communication through PCC are unavailable while its cloud connection is lost. The existing alarm can still be operated locally through its keypad, provided the alarm itself remains powered and operational.
Yes. PCC has an external antenna with an MMCX connection. The antenna can be positioned outside a metal control-panel enclosure to improve reception. The installer should check Wi-Fi signal strength during commissioning.
PCC is designed to fit discreetly inside a suitable existing control-panel enclosure. Adhesive pads secure the device, and its pre-wired leads connect to the panel.
PCC is powered from the panel’s auxiliary supply and operates at 9–15VDC. The installer must check that the supply has enough capacity for PCC and the other connected devices.
PCC can be installed in as little as 15 minutes on a suitable, prepared system. Actual time depends on panel wiring, programming, account setup and Wi-Fi availability.
PCC has two programmable trigger inputs and one changeover relay output, with normally open, common and normally closed connections. The relay is rated at 1A at 30VDC.
Each input can be configured for a positive or negative trigger, either applied or removed, to suit the connected panel output.
Yes. The relay supports pulsed and latched operation. Where the panel supports it, the installation guide recommends a keyswitch pulsed zone with a two-second relay pulse.
The recommended arrangement connects input 1 to the panel’s bell output for alarm notifications and input 2 to a ‘final set any’ output for armed-status feedback. The available panel outputs determine whether this arrangement is possible.
Yes. PCC can respond to suitable external triggers from equipment such as gates, garage doors and CCTV systems. The connected equipment must provide a compatible trigger, and PCC still needs a suitable power supply and Wi-Fi connection.
No. A suitable external device can trigger PCC directly. The installer must check the electrical compatibility of the contact or relay signal and configure the PCC input to match.
Yes. Its pulsed or latched relay can interface with a compatible control input on other equipment. The installer must check the required operation and relay rating. HomeControl2.0 can display lock/unlock or door open/close icons to suit the function.
Yes, provided the panel has a suitable output to trigger a PCC input. Keyswitch support is required for remote arming and disarming through the relay, but is not required just to send an input-triggered notification.
Yes. PCC supports over-the-air firmware updates through its network connection.
No. PCC itself is ungraded. Adding it does not upgrade the security grade of an existing alarm system.
The product code is DIGI-PCC. Installers can obtain PCC through Pyronix distributors; end users should contact their alarm installer to discuss suitability and installation.
The installer needs an active InSite Pro Cloud account with an approved organisation and the appropriate estate set up. The end user needs a PyronixCloud account. Both need HomeControl2.0, signed in with their respective accounts.
Yes. An organisation requiring installer-level access must be approved by the installer’s Pyronix Account Manager before it can be used. This should be arranged before attending site.
In HomeControl2.0, the installer selects ‘+’, then ‘Add PCC’, and connects over Bluetooth. Setup includes assigning the estate and customer, entering Wi-Fi details, creating a customer PIN, and configuring the inputs and relay.
The diagnostics screen displays the connected Wi-Fi network, Wi-Fi signal strength, relay status and the status of both inputs. These help the installer check connectivity and wiring operation.
Green indicates normal connected operation, blue indicates Bluetooth setup mode, and orange indicates Wi-Fi is disconnected. Yellow indicates network/server negotiation, white flashes show activity, and cyan flashes indicate a relay state change. Magenta can indicate receipt of network settings or an over-the-air update.
The stored Wi-Fi details must be updated. Holding the device button for five seconds enters Wi-Fi configuration mode, indicated by a blue LED, so the connection can be set up through HomeControl2.0. Holding it for ten seconds or more clears the stored Wi-Fi credentials.
PCC has a two-year warranty against defects in workmanship, subject to Pyronix’s standard warranty conditions.